Sign In | Join Free | My entremaqueros.com |
|
Brand Name : Endress+Hauser
Model Number : FTL31-AA4U3AAWBJ( FTL31-1530/0)
Certification : CE
Place of Origin : Germany
MOQ : 1pc
Price : negotiable
Payment Terms : T/T
Supply Ability : 100pcs per month
Delivery Time : 12-14weeks
Packaging Details : standard carton packing
Approval : Non-hazardous area
Power Supply; Output : 10-30VDC; 3-wire PNP
Electrical Connection : Valve plug ISO4400 M16, IP65 NEMA Type 4X Encl.
Sensor Design : Max. process temperature 150oC/302oF
Sensor Type : Compact version 316L Ra<3.2um/126uin
Process Connection : Thread ISO228 G1/2, 316L
Liquiphant FTL31 is a point level switch for liquids. The FTL31 is designed for industrial applications in all industries, mainly the machinery industry. The Liquiphant is used for overfill protection or pump dry-run protection in cleaning systems. The IO-Link capability allows easy parameter setting.
Compact:
- Smallest vibronic sensor in the market
Safe:
- Continuous self-monitoring
-Reliable switching independent of media properties
Easy:
- No calibration
- Plug & play
- IO-Link connectivity
Point level switch in compact design with stainless steel housing.
Process connections: Threads
Temperature: -40 to +150°C (-40 to +302°F)
Pressure: -1 to +40bar (-14.5 to 580psi)
Surface roughness: 3.2µm
Overfill protection and leakage detection WHG, marine approvals, final inspection report
Measuring principle |
Vibration Liquids |
Characteristic / Application |
Level switch for liquids and is used in tanks, vessels |
Supply / Communication |
|
Ambient temperature |
|
Process temperature |
-40 °C ... 150 °C |
Process pressure / max. overpressure limit |
Vacuum ... 40 bar |
Min. density of medium |
Min. density of medium |
Main wetted parts |
316L |
Process connection |
Threads: |
Communication |
AC/DC, DC-PNP |
Certificates / Approvals |
CSA C/US, EAC |
Safety approvals |
Overfill protection WHG |
Design approvals |
EN 10204-3.1 |
Marine approval |
ABS/ LR/ BV/ DNV |
Options |
Adjustment switching delay |
![]() |
Endress Hauser FTL31 Liquiphant Point Level Detection with G1/2 Thread ISO228 Connection Images |